FZW28-12F Outdoor Vacuum Load Switch
Selection Operating conditions 1. Altitude: ≤ 2000 meters; 2. Environment temperature: -40℃ ~+85℃; 3. Relative humidity: ≤ 90% (25℃); 4. The maximum daily temperature difference: 25℃; 5. Protection grade: IP67; 6. The maximum ice thickness: 10mm. Technical data Item Unit Parameter The switch body Rated voltage kV 12 Power frequency insulation withstand voltage (Interphase and phase to ground / fracture) kV 42/48 Lightning impulse withstand voltage (Interphase and phase to groun...
JXF Low-voltage Integrated Distribution Box
Selection Operating conditions 1. Installation Site: Indoor or outdoor; 2. Atitude: No more than 2000m. 3. Earthquake lntensity: No more than 8 degrees. 4. Ambient Temperature: No more than +40℃ and no less than -25℃.Averagetemperature is no more than +35℃ within 24 hours. 5. Relative Humidity: the average daily value is no more than 95%, the averagemonthly value is no more than 90%. 6. Installation locations: without fire,explosion danger,serious pollution,chemical corrosion and violent vi...
FLN36 Indoor SF6 Load Switch
Selection Operating conditions 1. Air temperature Maximum temperature: +40℃; Minimum temperature:-35℃. 2. Humidity Monthly average humidity 95%; Daily average humidity 90%. 3. Altitude above sea level Maximum installation altitude: 2500m. 4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 5. No frequent violent shake. Technical data Ratings Unit Value Rated voltage kV 12 24 40.5 Rated lighting impulse withstand voltage kV 75 125 170 Common value Acro...
YRM6-12/24 Gas-insulated Metal-enclosed Switchgear
Selection Operating conditions 1. Ambient air temperature: -40℃~+40℃; 2. Relative air humidity: daily average <95%, monthly average <90%; 3. Altitude ≤1500m (under standard inflation pressure); 4. Seismic intensity <9 class; 5. Places free from fire, explosion, serious contamination, chemical corrosion and severe vibration. Special conditions Manufacturers and end users must agree on special Operating conditions that are different from normal operating cond...
S9-M Series Oil-immersed Fully Sealed
Selection Operating conditions 1. Ambient temperature: maximum temperature: +40°C, minimum temperature: -25℃ . 2. Average temperature of the hottest month:+30℃, average temperature in the hottest year: +20℃ . 3. Altitude not exceeding 1000m. 4. The waveform of the power supply voltage is similar to a sine wave. 5. The three-phase supply voltage should be approximately symmetrical. 6. The total harmonic content of the load current shall not exceed 5% of the rated cur...
GW1 Outdoor Isolation Switch
Selection Operating conditions 1. The altitude above sea level: 2000m 2. The ambient air temperature: -40℃~40℃ wind speed does not exceed 35m/s. 3. The earthquake intensity does not exceed 8 degrees. 4. The working situation is without frequent violent vibration. 5. The installation site of ordinary type isolator s hould be kept away from gas, smoke chemical deposition, salt-spray fog, dust and other explosive and corrosive maters that affect seriously insulation an...