ZW20-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Altitude≤2000 meters 2. The environment temperature: -30℃ ~+55℃ outdoor; the highest annual average temperature 20 ℃, the highest daily average temperature 30 ℃; 3. Relative humidity: 95% (25℃) 4. Seismic capacity: horizontal ground acceleration 0.3g, vertical ground acceleration 0.15g, at the same time duration of three sine waves, a safety factor of 1.67 5. Earthquake intensity: 7 degrees 6. The maximum daily temperature difference: 25 ℃ 7. The intensity o...
RN1 Indoor Current Limiting Fuse
Features Current which passes the fuse when being1.3 times of itsspecified electric current,Do not fusing for an hour; Whenthe current through the fuse is 2 times of its specinedelectric current,fusing in an hour;Refer to its fusingfeature curve in chart 1when select the fuse. Figure 1 RN1/RN3“An-second” characteristic curve Technical data 3 6 10 35 Rated current (A) 20 100 200 300 400 200 75 100 200 300 20 50 75 100 200 7.5 10 20 30 40 Max breaking curent KV effective vakue 40 1.3...
ZN85-40.5 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient temperature -10℃ ~ +40℃ 2. Altitude ≤ 1500m; 3. Relative humidity: the daily average is not greater than 95%, the monthly average is not greater than 90%, the daily average of saturated steam is not greater than 2.2*10-³Mpa, and the monthly average is not greater than 1.8*10-³Mpa; 4. The earthquake intensity does not exceed 8 degrees; 5. Places free of fire, explosion hazards, severe pollution, chemical corrosion and severe vibrations. Features 1. Ad...
ZN63(VS1)-24 Indoor Vacuum Circuit Breaker
Selection ZN63 - 24 P / T 630 - 25 HT P210 Name - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) breaking current(KA) - Rated short-circuit Installation Main circuit wiring direction Indoor vacuum circuit breaker - 24:24KV No mark: Insulating cylinder type P: Solid-sealing type / T: Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 HT:Handcart type FT:Fixed type P210 P275 Note: Zn63 (S) adopts a double spring integral mechanism by default. If...
JN17 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m (sensor height:140mm) 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Dirtiness degree: II Technical data Item Units Data Rated voltage kV 12 Rated short time withstand current kA 40 Rated short circuit withstand time s 4 Rated short circuit making current kA 100 Rated peak withstand curren...
FLN36 Indoor SF6 Load Switch
Selection Operating conditions 1. Air temperature Maximum temperature: +40℃; Minimum temperature:-35℃. 2. Humidity Monthly average humidity 95%; Daily average humidity 90%. 3. Altitude above sea level Maximum installation altitude: 2500m. 4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 5. No frequent violent shake. Technical data Ratings Unit Value Rated voltage kV 12 24 40.5 Rated lighting impulse withstand voltage kV 75 125 170 Common value Acro...Medium and high voltage products are electrical equipment designed to handle voltages above the standard household voltage of 120V. These products are used in a variety of applications, including power generation, transmission, and distribution, as well as industrial and commercial settings.