XGN15-12~24 Air-insulated RMU(Fixed Type)
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ .Daily average temperature:≤35℃ . 2. Altitude: ≤1000m. 3. Relative humidity : Daily average≤95% ,daily averange of vapour pressure≤2.2kpa Monthly average≤90%,monthly averange of vapour pressure≤1.8kpa. 4. Earthquake intensity: ≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. Modular design, where each unit module c...
FZN25/FZRN25-12 Indoor Vacuum Load Switch
Selection Operating conditions 1. Ambient air temperature: upper limit +40℃, lower limit -25℃ (allow storage at – 30℃), 24h average value is not higher than +35℃; 2. Altitude: no more than 1000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Earthquake intensity: do not exceed 8 degree; 5. The surrounding air is not corrosive and flammable gas,steam and other significant pollution; 6. No regular violent vibration; 7. Cont...
YSM6-12~24 Air-insulated RMU(Fixed Type)
Selection Operating conditions 1. Air temperature: Maximum temperature: +40℃; Minimum temperature:-5℃ 2. Humidity: Monthly average humidity 95%; Daily average humidity 90% . 3. Altitude above sea level: Maximum installation altitude: 2000m 4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 5. No frequent violent shake Features 1. Incoming unit with switch disconnector(Load break switch) schemas With other extra components optional Outg...
LFS-10Q Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
ZN63M-12 (Magnetic type) Indoor Vacuum Circuit ...
Selection ZN63M - 12 P M 630 - 25 HT P210 Name Rated voltage(KV) Pole type Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV No mark: Insulating cylinder type P Solid -sealing type M: Insulating cylinder type permanent magne 630, 1250, 1600, 2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: The phase spacing of ZN63-12□M is usually P210mm, whic...
YVG-12 Solid Insulation Ring Network Cabinet
Selection Classified by functional units in the system: incoming cabinet, outgoing cabinet, buscouple cabinet, metering cabinet, PT cabinet, lifting cabinet, etc., represented by wiring scheme number. According to the type of main switch components, it is divided into: load switch cabinet, load switch fuse combination electrical cabinet, circuit breaker cabinet, and isolation switch cabinet, etc., represented by F (fuse combination electrical appliance), V (circuit breaker), C (load switch),...