RN2 Indoor Current Limiting Fuse
Technical data Product type RN2-3、6、10 RN2-15、20 RN2-35 Rated voltage 3 6 10 15 20 35 KV Fuse current A 0.5 0.5 0.5 Capacity of largest break of three-phase MVA 500 1000 1000 1000 Max break curent KA effective value KA 500 85 50 40 30 17 Overvoltage multiple Do not exceed voltage of 2.5 times of rating Resistance of the fuse pipe (Ω) 93±7 200±10 315土14 Weight Kg 5.6 12.2 15.6 Fuse weight Kg 0.9 1.6 2.5 Overall and mounting dimensions(mm)
KYN28-12 Metalclad AC Enclosed Switchgear, With...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ . 2. Altitude: ≤1000m. 3. Relative humidity : Daily average≤95%, daily averange of vapour pressure≤2.2kpa. 4. Earthquake intensity: ≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas and water vapor. 6. Used in place without frequently intense vibrant. Note: Customized products are available. Features 1. The cabinet is made of aluminum-zinc coated sheet processed by CNC equipment, andisassembled ...
JN15-24 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤2000m 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Class of pollution: II Technical data Item Units Data Rated voltage kV 24 Rated short time withstand current kA 31.5 Rated short circuit withstand time S 4 Rated short circuit making current kA 80 Rated peak withstand current kA 80 Rated 1min power frequency withstan...
JN17 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m (sensor height:140mm) 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Dirtiness degree: II Technical data Item Units Data Rated voltage kV 12 Rated short time withstand current kA 40 Rated short circuit withstand time s 4 Rated short circuit making current kA 100 Rated peak withstand curren...
GW1 Outdoor Isolation Switch
Selection Operating conditions 1. The altitude above sea level: 2000m 2. The ambient air temperature: -40℃~40℃ wind speed does not exceed 35m/s. 3. The earthquake intensity does not exceed 8 degrees. 4. The working situation is without frequent violent vibration. 5. The installation site of ordinary type isolator s hould be kept away from gas, smoke chemical deposition, salt-spray fog, dust and other explosive and corrosive maters that affect seriously insulation an...
KYN61-40.5 Metalclad AC Enclosed Switchgear, Wi...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ 2. Altitude: ≤1000m 3. Relative humidity : Daily average≤95%; Monthly average≤90% 4. Earthquake intensity:≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. The cabinet is made of aluminum-zinc coated sheet processed by CNC equipment and assembled with bolts or rivets, with a fully modular structure. 2. This switchgear has various functions to...