JN22-40.5/31.5 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Appliable in the place without corrosive, flammable gas and water place 6. With no frequently intense vibrant place around. Technical data Item Units Data Rated voltage kV 35 Maximum voltage kV 40.5 Rated short time withstand current kA 31.5 Rat...
VYF-12GD Indoor Three Position Vacuum Circuit B...
Selection Note: If there is no grounding switch, the grounding operation shaft acts as an interlocking shaft, and the external dimensions remain unchanged. Operating conditions ● Ambient temperature: -25℃ +40℃; ● Relative humidity: daily average <95%, monthly average <90%; ● Altitude: not higher than 1000m; ● Earthquake intensity: no more than 8 degrees: ● Place of use: No explosion hazard, chemical and severe vibration and pollution. ● Service conditions above an altitude of 1000 mete...
GCS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ Daily average temperature: ≤35℃ When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Altitude: ≤2000m 3. Relative humidity: ≤50%, when temperature is +40℃ When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation. 4. Installation inclination: ≤5% 5. Applicable in the...
S9-M Series Oil-immersed Fully Sealed
Selection Operating conditions 1. Ambient temperature: maximum temperature: +40°C, minimum temperature: -25℃ . 2. Average temperature of the hottest month:+30℃, average temperature in the hottest year: +20℃ . 3. Altitude not exceeding 1000m. 4. The waveform of the power supply voltage is similar to a sine wave. 5. The three-phase supply voltage should be approximately symmetrical. 6. The total harmonic content of the load current shall not exceed 5% of the rated cur...
S9-M Oil-immersed Transformer
Selection Operating conditions Ambient temperature: maximum temperature: +40°C, minimum temperature: -25℃. Average temperature of the hottest month:+30℃, average temperature in the hottest year: +20℃. Altitude not exceeding 1000m. The waveform of the power supply voltage is similar to a sine wave. The three-phase supply voltage should be approximately symmetrical. The total harmonic content of the load current shall not exceed 5% of the rated current. Where to use: indoors or outdoors. Featu...
SC(B)9 Series Epoxy Resin Dry-type Transformer
Selection Operating conditions 1. Ambient temperature: maximum temperature: +40°C, minimum temperature: -25℃ . 2. Average temperature of the hottest month:+30℃, average temperature in the hottest year:+20℃ . 3. Altitude not exceeding 1000m. 4. The waveform of the power supply voltage is similar to a sine wave. 5. The three-phase supply voltage should be approximately symmetrical. 6. The relative humidity of the surrounding air should be lower than 93%. 7. And there ...