FZW32-12(40.5) Outdoor Vacuum Load Switch
Selection Features FZW32-12 (40.5) type outdoor high voltage isolating vacuum load switch adopts the vacuum arc extinguish chamber, no explosion danger, no maintenance. The load switch isolation knife linkage with a three-phase vacuum interrupter, breaking and closing operation in good same period, and with reliable isolation fracture when breaking, namely has the function of isolation switch. Most of the switch body parts are made of stainless steel materials, the base frame is made by stai...
YBM22-12/0.4 Outdoor Prefabricated Substation (EU)
Selection Operating conditions 1. Ambient air temperature: -10℃ ~+40℃ 2. Altitude: ≤1000m 3. Solar radiation: ≤1000W/m² 4. Ice cover: ≤20mm 5. Wind speed: ≤35m/s 6. Relative humidity: Daily average relative humidity ≤95%. Monthly average relative humidity ≤90% Daily average relative water vapour pressure ≤2.2kPa. Monthly average relative water vapour pressure ≤1.8kPa 7. Earthquake intensity: ≤magnitude 8 8. Applicable in the places without corrosive and flammable gas Note: Customized product...
ZW7-40.5 Outdoor Vacuum Circuit Breaker
Operating conditions 1. Ambient temperature: upper limit +40℃, lower limit -30℃; Days difference does not exceed 32K; 2. Altitude: 1000m and the following areas; 3. Wind pressure: not more than 700Pa (corresponding to the wind speed 34m/s); 4. Air pollution level: IV class 5. Earthquake intensity: do not exceed 8 degree; 6. Ice thickness: no more than 10mm. Technical data Item Unit Parameter Voltage, current parameters Rated voltage kV 40.5 Rated short time power frequency withstan...
ZN63(VS1)-24 Indoor Vacuum Circuit Breaker
Selection ZN63 - 24 P / T 630 - 25 HT P210 Name - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) breaking current(KA) - Rated short-circuit Installation Main circuit wiring direction Indoor vacuum circuit breaker - 24:24KV No mark: Insulating cylinder type P: Solid-sealing type / T: Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 HT:Handcart type FT:Fixed type P210 P275 Note: Zn63 (S) adopts a double spring integral mechanism by default. If...
LZZBJ18 Current Transformer
Selection Technical data 1. Rated insulation level: 10kV:12/42/75kV; 20kV:24/65/125kV 2. Power factor of load: cosΦ=0.8(lagging) 3. Rated secondary current: 5A(or 2A,1A) LZZBJ18-10/150b/2 Type Rated primary current (A) 1s thermal current (kA virtual value) Dynamic standing current (kA peak) Accuracy class combination (1S/2S) Rated secondary output(VA) 0.2S 0.5 5P15 10P15 20 2 5 0.2/0.5/10P10 0.2/0.5/5P10 0.5/0.5/10P10 0.2/0.2/10P10 0.5/0.5/5P10 0.2/0.2/5P10 10 10 15 30 3 7.5 ...
ZN63M-12 (Magnetic type) Indoor Vacuum Circuit ...
Selection ZN63M - 12 P M 630 - 25 HT P210 Name Rated voltage(KV) Pole type Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV No mark: Insulating cylinder type P Solid -sealing type M: Insulating cylinder type permanent magne 630, 1250, 1600, 2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: The phase spacing of ZN63-12□M is usually P210mm, whic...