YB27-12/0.4 Outdoor Prefabricated Substation (US)
Selection Operating conditions 1. Ambient air temperature: -30℃ ~+40℃ 2. Altitude: ≤1000m 3. Wind speed:34m/s ≤700pa 4. Relative humidity: Daily average relative humidity ≤95%.Monthly average relative humidity ≤95%. 5. Installation inclination: ≤grade 8 6. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. Compact structure with small volume, the volume is 1/3-1/5 of European style substation in same capacity. It reduce the floo...
LZZBJ10 Current Transformer
Selection Technical data 1. The performance of products is conformed to IEC standard and GB1208-2006 2. Current Transformer. 3. Rated insulation level: 12/42/75kV 4. Rated frequency: 50Hz 5. Rated secondary current: 5A, 1A 6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC. Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA virtual value) Rated dynamic stability curr...
LFS-10Q Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
KYN28-24 Metalclad AC Enclosed Switchgear, With...
Selection Operating conditions 1. +15°C~+40°C. And the average value measured within 24 hours shall not exceed 35°C 2. The average monthly relative humidity shall not exceed 90% The average monthly water vapor pressure shall not exceed 1.8kPa; 3. Altitude: ≤1000m. 4. There is no obvious dust or smoke in the surrounding air: pollution caused by corrosive or combustible gases, vapors, or salt mist; 5. Vibration or ground motion from outside the switchgear and control equipment can be ignored; ...
FZW28-12F Outdoor Vacuum Load Switch
Selection Operating conditions 1. Altitude: ≤ 2000 meters; 2. Environment temperature: -40℃ ~+85℃; 3. Relative humidity: ≤ 90% (25℃); 4. The maximum daily temperature difference: 25℃; 5. Protection grade: IP67; 6. The maximum ice thickness: 10mm. Technical data Item Unit Parameter The switch body Rated voltage kV 12 Power frequency insulation withstand voltage (Interphase and phase to ground / fracture) kV 42/48 Lightning impulse withstand voltage (Interphase and phase to groun...
KYN61-40.5 Metalclad AC Enclosed Switchgear, Wi...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ 2. Altitude: ≤1000m 3. Relative humidity : Daily average≤95%; Monthly average≤90% 4. Earthquake intensity:≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. The cabinet is made of aluminum-zinc coated sheet processed by CNC equipment and assembled with bolts or rivets, with a fully modular structure. 2. This switchgear has various functions to...