LCT Current Transformer
Technical data 1. Operating environment a. Environmental temperature: -20℃~50℃; b. Relative humidity: ≤90% c. Atmospheric pressure: 80kpa~200kpa; 2. AC voltage: 66kV~4000kV; 3. Zero-sequence current:Primary side~36A (customize for 36A or above, secondary side 20~30mA) 4. Electric network frequence: 50Hz; 5. The terminal used with ML98 device-using explanation; System primary zero-sequence current(A) Selected terminal 1≤10<6 S1, S2 6≤10<12 S1, S3 12≤10<36 S1, S4 6. Secondary loa...
LZZBJ9-10 Current Transformer
Selection Technical data 1. The performance of products is conformed to IEC standard and GB1208-2006 Current Transformer. 2. Rated insulation level: 12/42/75kV 3. Load power factor: cosΦ =0.8(Lag) 4. Rated frequency: 50Hz 5. Rated secondary current: 5A, 1A 6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC. Model Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA vir...
GCS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ Daily average temperature: ≤35℃ When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Altitude: ≤2000m 3. Relative humidity: ≤50%, when temperature is +40℃ When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation. 4. Installation inclination: ≤5% 5. Applicable in the...
GW1 Outdoor Isolation Switch
Selection Operating conditions 1. The altitude above sea level: 2000m 2. The ambient air temperature: -40℃~40℃ wind speed does not exceed 35m/s. 3. The earthquake intensity does not exceed 8 degrees. 4. The working situation is without frequent violent vibration. 5. The installation site of ordinary type isolator s hould be kept away from gas, smoke chemical deposition, salt-spray fog, dust and other explosive and corrosive maters that affect seriously insulation an...
PRW1 Drop-out Fuse
Selection Operating conditions 1. Suitable for environments with an upper limit of 40 ℃ and a lower limit of -30 ℃ . 2. Altitude not exceeding 1000m, wind speed not exceeding 35m/s 3. Fuses are not suitable for the following locations 3.1 Places with fuel or explosion hazards. 3.2 Places with severe vibration or impact. 3.3 Areas with abnormal electrochemical gas effects and severe air pollution and smoke Technical data parameter of porcelain housed fuse Type Rated voltage (kV) Rated curr...
ZN63M-12 (Magnetic type) Indoor Vacuum Circuit ...
Selection ZN63M - 12 P M 630 - 25 HT P210 Name Rated voltage(KV) Pole type Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV No mark: Insulating cylinder type P Solid -sealing type M: Insulating cylinder type permanent magne 630, 1250, 1600, 2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: The phase spacing of ZN63-12□M is usually P210mm, whic...