LZZBJ10 Current Transformer
Selection Technical data 1. The performance of products is conformed to IEC standard and GB1208-2006 2. Current Transformer. 3. Rated insulation level: 12/42/75kV 4. Rated frequency: 50Hz 5. Rated secondary current: 5A, 1A 6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC. Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA virtual value) Rated dynamic stability curr...
FLN36 Indoor SF6 Load Switch
Selection Operating conditions 1. Air temperature Maximum temperature: +40℃; Minimum temperature:-35℃. 2. Humidity Monthly average humidity 95%; Daily average humidity 90%. 3. Altitude above sea level Maximum installation altitude: 2500m. 4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 5. No frequent violent shake. Technical data Ratings Unit Value Rated voltage kV 12 24 40.5 Rated lighting impulse withstand voltage kV 75 125 170 Common value Acro...
ZW32-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -30℃ 2. Altitude ≤ 2000 meters 3. Wind pressure: no more than 700Pa (corresponding to the wind speed 34m/s) 4. Earthquake intensity: do not exceed 8 degree 5. Pollution grade: III class 6. Maximum daily temperature: less than 25℃ . Technical data Item Unit Parameter Voltage, current parameters Rated voltage kV 12 Rated short time power frequency withstand voltage (1min) kV 42/48 Rated l...
FZW32-12(40.5) Outdoor Vacuum Load Switch
Selection Features FZW32-12 (40.5) type outdoor high voltage isolating vacuum load switch adopts the vacuum arc extinguish chamber, no explosion danger, no maintenance. The load switch isolation knife linkage with a three-phase vacuum interrupter, breaking and closing operation in good same period, and with reliable isolation fracture when breaking, namely has the function of isolation switch. Most of the switch body parts are made of stainless steel materials, the base frame is made by stai...
FN AC High-voltage Load Switch
Selection Technical data Rated voltage(kV) Highest voltage(kV) Rated current(A) Industrial frequency voltage withstand in 1min(kV) 4S thermal stable current (effective value)(A) 12 12 400 42/48 12.5 12 12 630 42/48 20 Active stable current (peak value)(A) Short circuit close current (A) Rated open current (A) Rated transfer current (A) 31.5 31.5 400 1000 50 50 630 1000 Type Full type DS Earthing switch at inlet position DX Earthing switch at inlet position L Interlock...
RN1 Indoor Current Limiting Fuse
Features Current which passes the fuse when being1.3 times of itsspecified electric current,Do not fusing for an hour; Whenthe current through the fuse is 2 times of its specinedelectric current,fusing in an hour;Refer to its fusingfeature curve in chart 1when select the fuse. Figure 1 RN1/RN3“An-second” characteristic curve Technical data 3 6 10 35 Rated current (A) 20 100 200 300 400 200 75 100 200 300 20 50 75 100 200 7.5 10 20 30 40 Max breaking curent KV effective vakue 40 1.3...