XRNT Current-limiting Fuses for Transformer Pro...
Selection Technical data Type Rated voltage Rated current of the fuse (A) Rated current of the fuselink (A) XRNT-12 12 40 3.15、6.3、10、16、20、25、31.5、40 XRNT-12 12 100 50、63、71、80、100、(125) XRNT-12 12 125 125、160、200、250 XRNT-24 24 200 3.15、6.3、10、16、20、25、31.5、40、50、63、80、100、125、160、200 XRNT–40.5 40.5 125 3.15、6.3、10、16、20、25、31.5、40、50、63、80、100、125、160、200 Overall and mounting dimensions(mm) Chat1/a link XRNT-12Kv Chat2/a li...
ZW8-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient temperature: upper limit +40℃, lower limit -30℃; 2. Altitude ≤ 2000 meters 3. Pressure: not more than 700Pa (corresponding to the wind speed 34m/s); 4. Earthquake intensity: do not exceed 8 degree; 5. Pollution grade: III class; 6. Maximum daily temperature variety less than 25℃. Technical data Item Unit Parameter Voltage, current parameters Rated voltage kV 12 Rated short time power frequency withstand voltage (1min) kV 42 Rated lightn...
GW5 Outdoor Isolation Switch
Selection Operating conditions 1. The ambient temperature: upper limit +40℃,lower limit -40 ℃; 2. Altitude: no more than 3000m; 3. Wind speed: not more than 35m/s; 4. Earthquake intensity: do not exceed 8 degree; 5. Pollution level: no more than III; 6. No severe vibration, no corrosive gas, no fire, no explosion danger place. Technical data Item Parameters Unit GW5- 40.5 GW5-72.5 GW5-126 GW5-145 Rated voltage kV 40.5 72.5 126 145 Rated current A 630/1250/1600/2000 Rated frequenc...
RN2 Indoor Current Limiting Fuse
Technical data Product type RN2-3、6、10 RN2-15、20 RN2-35 Rated voltage 3 6 10 15 20 35 KV Fuse current A 0.5 0.5 0.5 Capacity of largest break of three-phase MVA 500 1000 1000 1000 Max break curent KA effective value KA 500 85 50 40 30 17 Overvoltage multiple Do not exceed voltage of 2.5 times of rating Resistance of the fuse pipe (Ω) 93±7 200±10 315土14 Weight Kg 5.6 12.2 15.6 Fuse weight Kg 0.9 1.6 2.5 Overall and mounting dimensions(mm)
XRNP Current-limiting Fuses for Voltage Transfo...
Selection Technical data Type Rated voltage(Kv) Rated current(A) Rated break current(KA) Dimensions XRNP1- □/□-□-1 7.2 (3.6) 12 0.2、0.3、0.5、1、2、3.15 50 See figure 1 XRNP1- □/□-□-1 24 0.2、0.3、0.5、1、2、3.15 50 See figure 2 XRNP1- □/□-□-2 12 2、3.15 50 See figure 3 XRNP6- □/□-□-1 40.5 0.2、0.3、0.5、1、2、3.15 31.5 See figure 4( Φ25 ) XRNP6- □/□-□-3 0.2、0.3、0.5、1、2、3.15、4、5 See figure 5 ( Φ30 ) XRNP6- □/□-□-4 0.2/0.5/1/2/3.15/5/6.3 See figure 6 ( Φ41 ) Note: 7....
ZN63 (VS1)-12C Vacuum Circuit Breaker (Side-Ope...
Selection ZN63 C - 12 P / T 630 - 25 FT R P210 Name Structure - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) - Rated short-circuit breaking current(KA) Installation Main circuit wiring direction Phase distance Indoor vacuum circuit breaker Side operation - 12:12KV No mark: Insulating cylinder type P: Solid-sealing type / T:Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 FT: Fixed type L: Left R: Right P210 Note: 1. order a ZN63 si...