GN30-12 Indoor Isolation Switch
Selection Operating conditions 1. The altitude does not exceed 1000m; 2. Ambient air temperature: -10 ℃ ~+40 ℃; 3. Relative humidity: daily average value is not greater than 95%, monthly average value is not greater than 90%; 4. Contamination grades: no serious dust, corrosive and explosive material place; 5. Earthquake intensity: do not exceed 8 degree; No regular violent vibration place. Technical data Product specifications Parameter GN30-12/ 400-12.5 GN30-12/ 630-12.5 GN30-12/ 1000-1...
ZW32-24 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient air temperature: The daily temperature variation: -40℃ ~+40℃ diurnal variation of temperature less than 25℃; 2. Altitude: no more than 2000 meters 3. Wind speed is no more than 35m/s (equivalent to 700Pa on the surface of the cylindrical); 4. Ice cover thickness no more than 10mm; 5. The intensity of sunshine not more than 1000W/m ² 6. Pollution degree no more than GB 5582 IV class 7. Seismic intensity does not exceed 8 class 8. No flammable, explosi...
JN15-12 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m (sensor height:140mm) 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Dirtiness degree: II Technical data Item Units Data Rated voltage kV 12 Rated short time withstand current kA 31.5 Rated short circuit withstand time s 4 Rated short circuit making current kA 80 Rated peak withstand current kA 80 Rated 1min powe...
ZN28-12 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -15℃; 2. Altitude: ≤2000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Earthquake intensity: less than 8 degrees; 5. No fire, explosion, pollution, chemical corrosion and severe vibration place. Technical data Item Unit Parameter Parameters of voltage, current, life Rated voltage kV 12 Rated short time power frequency with...
YRM6-12/24 Gas-insulated Metal-enclosed Switchgear
Selection Operating conditions 1. Ambient air temperature: -40℃~+40℃; 2. Relative air humidity: daily average <95%, monthly average <90%; 3. Altitude ≤1500m (under standard inflation pressure); 4. Seismic intensity <9 class; 5. Places free from fire, explosion, serious contamination, chemical corrosion and severe vibration. Special conditions Manufacturers and end users must agree on special Operating conditions that are different from normal operating cond...
KYN61-40.5 Metalclad AC Enclosed Switchgear, Wi...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ 2. Altitude: ≤1000m 3. Relative humidity : Daily average≤95%; Monthly average≤90% 4. Earthquake intensity:≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. The cabinet is made of aluminum-zinc coated sheet processed by CNC equipment and assembled with bolts or rivets, with a fully modular structure. 2. This switchgear has various functions to...