YVG-12 Solid Insulation Ring Network Cabinet
Selection Classified by functional units in the system: incoming cabinet, outgoing cabinet, buscouple cabinet, metering cabinet, PT cabinet, lifting cabinet, etc., represented by wiring scheme number. According to the type of main switch components, it is divided into: load switch cabinet, load switch fuse combination electrical cabinet, circuit breaker cabinet, and isolation switch cabinet, etc., represented by F (fuse combination electrical appliance), V (circuit breaker), C (load switch),...
XL Low Voltage Power Distribution Cabinet
Selection Operating conditions 1. Environmental Conditions1.Installation Site: Indoor; 2. Altitude: No more than 2000m. 3. Earthquake lntensity: No more than 8 degrees. 4. Ambient Temperature: No more than +40℃ and no less than -15℃ . Averagetemperature is no more than +35℃ within 24 hours. 5. Relative Humidity: the average daily value is no more than 95%, the averagemonthly value is no more than 90%. 6. Installation locations: without fire,explosion danger,serious pollution,chemical corros...
ZN63(VS1)-12 Indoor Vacuum Circuit Breaker (Ins...
Selection ZN63 - 12 T 630 - 25 HT P210 Model Rated voltage(KV) Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV T: Spring type 630,1250, 1600,2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: ZN63-12 adopts a double spring integrated mechanism by default. If a single spring modular mechanism is required, a single spring needs to be added to the mod...
MNS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. lnstallation Site: Indoor; 2. Altitude: No more than 2000m. 3. Earthquake lntensity: No more than 8 degrees. 4. Ambient Temperature: No more than +40℃ and no less than -15℃.Averagetemperature is no more than +35℃ within 24 hours. 5. Pelative Humidity: the average daily value is no more than 95%, the averagemonthlyvalue is no more than 90%. 6. Installation lacations: without fire,explosion danger,serious pollution,chemical corrosion and violent vibration. Fe...
XGN15-12~24 Air-insulated RMU(Fixed Type)
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ .Daily average temperature:≤35℃ . 2. Altitude: ≤1000m. 3. Relative humidity : Daily average≤95% ,daily averange of vapour pressure≤2.2kpa Monthly average≤90%,monthly averange of vapour pressure≤1.8kpa. 4. Earthquake intensity: ≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. Modular design, where each unit module c...
FXB Polymer Insulators
Technical data Type Ratde current (kv) Ratde machincal load(kN) Height (mm) Insulating Li(mm) FXBW2-12/70UC 12 70 350 180 FXB2-15/70UD 15 70 375 200 FXB2-24/70UD 24 70 430 290 FXB2-28/70UD 28 70 430 290 FXB2-33/70UD 33 70 550 360 FXB2-35/70UD 36 70 570 400 FXBO2-36/70 36 70 650 450 Type Min. creepage distance (mm) Diameter of shed D.(mm) Full wave lighting requency wet withsand vltage (peak)KV 1min Power requency wet withstand voltage (peak value)KV FXBW2-12/70UC...