YRM6-12/24 Gas-insulated Metal-enclosed Switchgear
Selection Operating conditions 1. Ambient air temperature: -40℃~+40℃; 2. Relative air humidity: daily average <95%, monthly average <90%; 3. Altitude ≤1500m (under standard inflation pressure); 4. Seismic intensity <9 class; 5. Places free from fire, explosion, serious contamination, chemical corrosion and severe vibration. Special conditions Manufacturers and end users must agree on special Operating conditions that are different from normal operating cond...
LZZBJ18 Current Transformer
Selection Technical data 1. Rated insulation level: 10kV:12/42/75kV; 20kV:24/65/125kV 2. Power factor of load: cosΦ=0.8(lagging) 3. Rated secondary current: 5A(or 2A,1A) LZZBJ18-10/150b/2 Type Rated primary current (A) 1s thermal current (kA virtual value) Dynamic standing current (kA peak) Accuracy class combination (1S/2S) Rated secondary output(VA) 0.2S 0.5 5P15 10P15 20 2 5 0.2/0.5/10P10 0.2/0.5/5P10 0.5/0.5/10P10 0.2/0.2/10P10 0.5/0.5/5P10 0.2/0.2/5P10 10 10 15 30 3 7.5 ...
JN15-24 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤2000m 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Class of pollution: II Technical data Item Units Data Rated voltage kV 24 Rated short time withstand current kA 31.5 Rated short circuit withstand time S 4 Rated short circuit making current kA 80 Rated peak withstand current kA 80 Rated 1min power frequency withstan...
ZN63(VS1)-24 Indoor Vacuum Circuit Breaker
Selection ZN63 - 24 P / T 630 - 25 HT P210 Name - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) breaking current(KA) - Rated short-circuit Installation Main circuit wiring direction Indoor vacuum circuit breaker - 24:24KV No mark: Insulating cylinder type P: Solid-sealing type / T: Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 HT:Handcart type FT:Fixed type P210 P275 Note: Zn63 (S) adopts a double spring integral mechanism by default. If...
GCS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ Daily average temperature: ≤35℃ When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Altitude: ≤2000m 3. Relative humidity: ≤50%, when temperature is +40℃ When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation. 4. Installation inclination: ≤5% 5. Applicable in the...
LZZBJ9-10 Current Transformer
Selection Technical data 1. The performance of products is conformed to IEC standard and GB1208-2006 Current Transformer. 2. Rated insulation level: 12/42/75kV 3. Load power factor: cosΦ =0.8(Lag) 4. Rated frequency: 50Hz 5. Rated secondary current: 5A, 1A 6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC. Model Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA vir...