LFSB-10 Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
JN17 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m (sensor height:140mm) 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Dirtiness degree: II Technical data Item Units Data Rated voltage kV 12 Rated short time withstand current kA 40 Rated short circuit withstand time s 4 Rated short circuit making current kA 100 Rated peak withstand curren...
XRNT Current-limiting Fuses for Transformer Pro...
Selection Technical data Type Rated voltage Rated current of the fuse (A) Rated current of the fuselink (A) XRNT-12 12 40 3.15、6.3、10、16、20、25、31.5、40 XRNT-12 12 100 50、63、71、80、100、(125) XRNT-12 12 125 125、160、200、250 XRNT-24 24 200 3.15、6.3、10、16、20、25、31.5、40、50、63、80、100、125、160、200 XRNT–40.5 40.5 125 3.15、6.3、10、16、20、25、31.5、40、50、63、80、100、125、160、200 Overall and mounting dimensions(mm) Chat1/a link XRNT-12Kv Chat2/a li...
LFS-10Q Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
GCK Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -5℃ ~+40℃ . Daily average temperature: ≤35℃. When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Transport and store temperature: -25℃ ~+55℃ . do not exceed +70℃ in short time. 3. Altitude: ≤2000m. 4. Relative humidity : ≤50%, when temperature is +40℃. When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 9...
LZZBJ10 Current Transformer
Selection Technical data 1. The performance of products is conformed to IEC standard and GB1208-2006 2. Current Transformer. 3. Rated insulation level: 12/42/75kV 4. Rated frequency: 50Hz 5. Rated secondary current: 5A, 1A 6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC. Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA virtual value) Rated dynamic stability curr...