YSM6-12~24 Air-insulated RMU(Fixed Type)
Selection Operating conditions 1. Air temperature: Maximum temperature: +40℃; Minimum temperature:-5℃ 2. Humidity: Monthly average humidity 95%; Daily average humidity 90% . 3. Altitude above sea level: Maximum installation altitude: 2000m 4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 5. No frequent violent shake Features 1. Incoming unit with switch disconnector(Load break switch) schemas With other extra components optional Outg...
RN1 Indoor Current Limiting Fuse
Features Current which passes the fuse when being1.3 times of itsspecified electric current,Do not fusing for an hour; Whenthe current through the fuse is 2 times of its specinedelectric current,fusing in an hour;Refer to its fusingfeature curve in chart 1when select the fuse. Figure 1 RN1/RN3“An-second” characteristic curve Technical data 3 6 10 35 Rated current (A) 20 100 200 300 400 200 75 100 200 300 20 50 75 100 200 7.5 10 20 30 40 Max breaking curent KV effective vakue 40 1.3...
MNS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. lnstallation Site: Indoor; 2. Altitude: No more than 2000m. 3. Earthquake lntensity: No more than 8 degrees. 4. Ambient Temperature: No more than +40℃ and no less than -15℃.Averagetemperature is no more than +35℃ within 24 hours. 5. Pelative Humidity: the average daily value is no more than 95%, the averagemonthlyvalue is no more than 90%. 6. Installation lacations: without fire,explosion danger,serious pollution,chemical corrosion and violent vibration. Fe...
XGN15-12~24 Air-insulated RMU(Fixed Type)
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ .Daily average temperature:≤35℃ . 2. Altitude: ≤1000m. 3. Relative humidity : Daily average≤95% ,daily averange of vapour pressure≤2.2kpa Monthly average≤90%,monthly averange of vapour pressure≤1.8kpa. 4. Earthquake intensity: ≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. Modular design, where each unit module c...
ZN28-12 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -15℃; 2. Altitude: ≤2000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Earthquake intensity: less than 8 degrees; 5. No fire, explosion, pollution, chemical corrosion and severe vibration place. Technical data Item Unit Parameter Parameters of voltage, current, life Rated voltage kV 12 Rated short time power frequency with...
ZN85-40.5 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient temperature -10℃ ~ +40℃ 2. Altitude ≤ 1500m; 3. Relative humidity: the daily average is not greater than 95%, the monthly average is not greater than 90%, the daily average of saturated steam is not greater than 2.2*10-³Mpa, and the monthly average is not greater than 1.8*10-³Mpa; 4. The earthquake intensity does not exceed 8 degrees; 5. Places free of fire, explosion hazards, severe pollution, chemical corrosion and severe vibrations. Features 1. Ad...