ZW20-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Altitude≤2000 meters 2. The environment temperature: -30℃ ~+55℃ outdoor; the highest annual average temperature 20 ℃, the highest daily average temperature 30 ℃; 3. Relative humidity: 95% (25℃) 4. Seismic capacity: horizontal ground acceleration 0.3g, vertical ground acceleration 0.15g, at the same time duration of three sine waves, a safety factor of 1.67 5. Earthquake intensity: 7 degrees 6. The maximum daily temperature difference: 25 ℃ 7. The intensity o...ZN63(VS1)-12 Indoor Vacuum Circuit Breaker (Ins...
Selection ZN63 - 12 T 630 - 25 HT P210 Model Rated voltage(KV) Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV T: Spring type 630,1250, 1600,2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: ZN63-12 adopts a double spring integrated mechanism by default. If a single spring modular mechanism is required, a single spring needs to be added to the mod...ZN23-40.5 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -15℃ (cold area -25℃); 2. Altitude: not more than 2000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Saturated steam pressure: daily average value is not higher than 2.2 × 10 -3 Mpa,monthly average is not higher than 1.8×10-3 Mpa; 5. Earthquake intensity does not exceed 8 degrees; 6. No fire, explosion, pollution, chemical corrosion a...ZW7-40.5 Outdoor Vacuum Circuit Breaker
Operating conditions 1. Ambient temperature: upper limit +40℃, lower limit -30℃; Days difference does not exceed 32K; 2. Altitude: 1000m and the following areas; 3. Wind pressure: not more than 700Pa (corresponding to the wind speed 34m/s); 4. Air pollution level: IV class 5. Earthquake intensity: do not exceed 8 degree; 6. Ice thickness: no more than 10mm. Technical data Item Unit Parameter Voltage, current parameters Rated voltage kV 40.5 Rated short time power frequency withstan...ZN63M-12 (Magnetic type) Indoor Vacuum Circuit ...
Selection ZN63M - 12 P M 630 - 25 HT P210 Name Rated voltage(KV) Pole type Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV No mark: Insulating cylinder type P Solid -sealing type M: Insulating cylinder type permanent magne 630, 1250, 1600, 2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: The phase spacing of ZN63-12□M is usually P210mm, whic...ZN63(VS1)-12S Indoor Vacuum Circuit Breaker (P...
Selection ZN63(VS1) - 12 P T 630 - 25 HT P210 Name Rated voltage(KV) Pole type Operating mechanism Rated current(A) Rated short-circuit breaking current(KA) Installation Phase spacing Indoor vacuum circuit breaker 12:12KV P:Solid -sealing type T: Spring type 630, 1250, 1600, 2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: Fixed type P150, P210, P275 Note: ZN63(VS1)-12P adopts a double spring integrated mechanism by default. If a single spring...