FZN21/FZRN21-12 Indoor Vacuum Load Switch
Selection Operating conditions 1. Altitude: no more than 1000m; 2. The environment temperature: upper limit +40℃, lower limit -30℃; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Saturated steam pressure: daily average value is not higher than 2.2×10 -3 Mpa, monthly average is not higher than 1.8×10 -3 Mpa; 5. No severe vibration, no corrosive gas, no fire, no explosion danger place. Technical data Item Unit Parameter Techn...
GW5 Outdoor Isolation Switch
Selection Operating conditions 1. The ambient temperature: upper limit +40℃,lower limit -40 ℃; 2. Altitude: no more than 3000m; 3. Wind speed: not more than 35m/s; 4. Earthquake intensity: do not exceed 8 degree; 5. Pollution level: no more than III; 6. No severe vibration, no corrosive gas, no fire, no explosion danger place. Technical data Item Parameters Unit GW5- 40.5 GW5-72.5 GW5-126 GW5-145 Rated voltage kV 40.5 72.5 126 145 Rated current A 630/1250/1600/2000 Rated frequenc...
ZW8-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient temperature: upper limit +40℃, lower limit -30℃; 2. Altitude ≤ 2000 meters 3. Pressure: not more than 700Pa (corresponding to the wind speed 34m/s); 4. Earthquake intensity: do not exceed 8 degree; 5. Pollution grade: III class; 6. Maximum daily temperature variety less than 25℃. Technical data Item Unit Parameter Voltage, current parameters Rated voltage kV 12 Rated short time power frequency withstand voltage (1min) kV 42 Rated lightn...
ZN23-40.5 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -15℃ (cold area -25℃); 2. Altitude: not more than 2000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Saturated steam pressure: daily average value is not higher than 2.2 × 10 -3 Mpa,monthly average is not higher than 1.8×10-3 Mpa; 5. Earthquake intensity does not exceed 8 degrees; 6. No fire, explosion, pollution, chemical corrosion a...
XRNM1 Current-Limiting Fuses for Motor Protection
Selection Technical data Rated voltage(Kv) Rated break current KA Rated current of the fuse (A) Rated current of the fuse link (A) Major dimensions A B C D XRNM1-3.6 3.6 50 125 50,63,100,125 337(390) 254(312) 305(340) 51 200 125,160,200 76 400 250,315,355,400 XRNM1-7.2 7.2 12 160 25,31.5,40,50,63,80,100,125,160 486(500) 403(461) 454(150) 76 315 200,224,250,315 Note: 1. The aboveid rated parameters for single pipe, the fuses can be parallel connected by on-site ...
GCK Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -5℃ ~+40℃ . Daily average temperature: ≤35℃. When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Transport and store temperature: -25℃ ~+55℃ . do not exceed +70℃ in short time. 3. Altitude: ≤2000m. 4. Relative humidity : ≤50%, when temperature is +40℃. When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 9...