FZN21/FZRN21-12 Indoor Vacuum Load Switch
Selection Operating conditions 1. Altitude: no more than 1000m; 2. The environment temperature: upper limit +40℃, lower limit -30℃; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Saturated steam pressure: daily average value is not higher than 2.2×10 -3 Mpa, monthly average is not higher than 1.8×10 -3 Mpa; 5. No severe vibration, no corrosive gas, no fire, no explosion danger place. Technical data Item Unit Parameter Techn...
JN15-12 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m (sensor height:140mm) 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Dirtiness degree: II Technical data Item Units Data Rated voltage kV 12 Rated short time withstand current kA 31.5 Rated short circuit withstand time s 4 Rated short circuit making current kA 80 Rated peak withstand current kA 80 Rated 1min powe...
YRM6-12/24 Gas-insulated Metal-enclosed Switchgear
Selection Operating conditions 1. Ambient air temperature: -40℃~+40℃; 2. Relative air humidity: daily average <95%, monthly average <90%; 3. Altitude ≤1500m (under standard inflation pressure); 4. Seismic intensity <9 class; 5. Places free from fire, explosion, serious contamination, chemical corrosion and severe vibration. Special conditions Manufacturers and end users must agree on special Operating conditions that are different from normal operating cond...
LFS-10Q Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
JN15-24 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤2000m 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Class of pollution: II Technical data Item Units Data Rated voltage kV 24 Rated short time withstand current kA 31.5 Rated short circuit withstand time S 4 Rated short circuit making current kA 80 Rated peak withstand current kA 80 Rated 1min power frequency withstan...
GW5 Outdoor Isolation Switch
Selection Operating conditions 1. The ambient temperature: upper limit +40℃,lower limit -40 ℃; 2. Altitude: no more than 3000m; 3. Wind speed: not more than 35m/s; 4. Earthquake intensity: do not exceed 8 degree; 5. Pollution level: no more than III; 6. No severe vibration, no corrosive gas, no fire, no explosion danger place. Technical data Item Parameters Unit GW5- 40.5 GW5-72.5 GW5-126 GW5-145 Rated voltage kV 40.5 72.5 126 145 Rated current A 630/1250/1600/2000 Rated frequenc...