MNS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. lnstallation Site: Indoor; 2. Altitude: No more than 2000m. 3. Earthquake lntensity: No more than 8 degrees. 4. Ambient Temperature: No more than +40℃ and no less than -15℃.Averagetemperature is no more than +35℃ within 24 hours. 5. Pelative Humidity: the average daily value is no more than 95%, the averagemonthlyvalue is no more than 90%. 6. Installation lacations: without fire,explosion danger,serious pollution,chemical corrosion and violent vibration. Fe...
KYN28-24 Metalclad AC Enclosed Switchgear, With...
Selection Operating conditions 1. +15°C~+40°C. And the average value measured within 24 hours shall not exceed 35°C 2. The average monthly relative humidity shall not exceed 90% The average monthly water vapor pressure shall not exceed 1.8kPa; 3. Altitude: ≤1000m. 4. There is no obvious dust or smoke in the surrounding air: pollution caused by corrosive or combustible gases, vapors, or salt mist; 5. Vibration or ground motion from outside the switchgear and control equipment can be ignored; ...
GN30-12 Indoor Isolation Switch
Selection Operating conditions 1. The altitude does not exceed 1000m; 2. Ambient air temperature: -10 ℃ ~+40 ℃; 3. Relative humidity: daily average value is not greater than 95%, monthly average value is not greater than 90%; 4. Contamination grades: no serious dust, corrosive and explosive material place; 5. Earthquake intensity: do not exceed 8 degree; No regular violent vibration place. Technical data Product specifications Parameter GN30-12/ 400-12.5 GN30-12/ 630-12.5 GN30-12/ 1000-1...
FZN25/FZRN25-12 Indoor Vacuum Load Switch
Selection Operating conditions 1. Ambient air temperature: upper limit +40℃, lower limit -25℃ (allow storage at – 30℃), 24h average value is not higher than +35℃; 2. Altitude: no more than 1000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Earthquake intensity: do not exceed 8 degree; 5. The surrounding air is not corrosive and flammable gas,steam and other significant pollution; 6. No regular violent vibration; 7. Cont...
GW1 Outdoor Isolation Switch
Selection Operating conditions 1. The altitude above sea level: 2000m 2. The ambient air temperature: -40℃~40℃ wind speed does not exceed 35m/s. 3. The earthquake intensity does not exceed 8 degrees. 4. The working situation is without frequent violent vibration. 5. The installation site of ordinary type isolator s hould be kept away from gas, smoke chemical deposition, salt-spray fog, dust and other explosive and corrosive maters that affect seriously insulation and conduction capability of...
YRM6-12/24 Gas-insulated Metal-enclosed Switchgear
Selection Operating conditions 1. Ambient air temperature: -40℃~+40℃; 2. Relative air humidity: daily average <95%, monthly average <90%; 3. Altitude ≤1500m (under standard inflation pressure); 4. Seismic intensity <9 class; 5. Places free from fire, explosion, serious contamination, chemical corrosion and severe vibration. Special conditions Manufacturers and end users must agree on special Operating conditions that are different from normal operating cond...