GW9 Outdoor Isolation Switch
Selection Operating conditions 1. The altitude does not exceed 1000m. 2. The ambien t air temperature: Maximum+40℃: Minimum: General Area-30℃, Paramos-40℃ . 3. The wind pressure does not exceed 700Pa. 4. The earthquake intensity does not exceed 8 degrees. 5. The working situation without frequent violent vibration. 6. The installation site of ordinary type isolator s hould be kept away from gas,smoke chemical deposition, salt-spray-fog, dust and other and corrosive maters that affect serious...
XRNT Current-limiting Fuses for Transformer Pro...
Selection Technical data Type Rated voltage Rated current of the fuse (A) Rated current of the fuselink (A) XRNT-12 12 40 3.15、6.3、10、16、20、25、31.5、40 XRNT-12 12 100 50、63、71、80、100、(125) XRNT-12 12 125 125、160、200、250 XRNT-24 24 200 3.15、6.3、10、16、20、25、31.5、40、50、63、80、100、125、160、200 XRNT–40.5 40.5 125 3.15、6.3、10、16、20、25、31.5、40、50、63、80、100、125、160、200 Overall and mounting dimensions(mm) Chat1/a link XRNT-12Kv Chat2/a li...
ZW32Y-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient temperature: upper limit +40℃, lower limit -30℃; 2. Altitude: ≤2000m; 3. Wind pressure: not more than 700Pa (corresponding to the wind speed 34m/s); 4. Earthquake intensity: do not exceed 8 degree; 5. Pollution grade: III class; 6. Maximum daily temperature variety less than 25℃ . Technical data Item Unit Parameter Rated voltage kV 12 Rated insulation level 1min power frequency withstand voltage Dry test Wet test kV 42/ fracture 48 kV 34 ...
LFS-10Q Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
PRW1 Drop-out Fuse
Selection Operating conditions 1. Suitable for environments with an upper limit of 40 ℃ and a lower limit of -30 ℃ . 2. Altitude not exceeding 1000m, wind speed not exceeding 35m/s 3. Fuses are not suitable for the following locations 3.1 Places with fuel or explosion hazards. 3.2 Places with severe vibration or impact. 3.3 Areas with abnormal electrochemical gas effects and severe air pollution and smoke Technical data parameter of porcelain housed fuse Type Rated voltage (kV) Rated curr...
ZN63(VS1)-24 Indoor Vacuum Circuit Breaker
Selection ZN63 - 24 P / T 630 - 25 HT P210 Name - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) breaking current(KA) - Rated short-circuit Installation Main circuit wiring direction Indoor vacuum circuit breaker - 24:24KV No mark: Insulating cylinder type P: Solid-sealing type / T: Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 HT:Handcart type FT:Fixed type P210 P275 Note: Zn63 (S) adopts a double spring integral mechanism by default. If...