GGD Low Voltage Power Distribution Cabinet
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ Daily average temperature: ≤35℃ When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Transport and store temperature: -25℃ ~+55℃ . do not exceed +70℃ in short time. 3. Altitude: ≤2000m 4. Relative humidity: ≤50%, when temperature is +40℃ When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature chang...
PRW1 Drop-out Fuse
Selection Operating conditions 1. Suitable for environments with an upper limit of 40 ℃ and a lower limit of -30 ℃ . 2. Altitude not exceeding 1000m, wind speed not exceeding 35m/s 3. Fuses are not suitable for the following locations 3.1 Places with fuel or explosion hazards. 3.2 Places with severe vibration or impact. 3.3 Areas with abnormal electrochemical gas effects and severe air pollution and smoke Technical data parameter of porcelain housed fuse Type Rated voltage (kV) Rated curr...
FZW32-12(40.5) Outdoor Vacuum Load Switch
Selection Features FZW32-12 (40.5) type outdoor high voltage isolating vacuum load switch adopts the vacuum arc extinguish chamber, no explosion danger, no maintenance. The load switch isolation knife linkage with a three-phase vacuum interrupter, breaking and closing operation in good same period, and with reliable isolation fracture when breaking, namely has the function of isolation switch. Most of the switch body parts are made of stainless steel materials, the base frame is made by stai...
JN15-12 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m (sensor height:140mm) 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Dirtiness degree: II Technical data Item Units Data Rated voltage kV 12 Rated short time withstand current kA 31.5 Rated short circuit withstand time s 4 Rated short circuit making current kA 80 Rated peak withstand current kA 80 Rated 1min powe...
XGN15-12~24 Air-insulated RMU(Fixed Type)
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ .Daily average temperature:≤35℃ . 2. Altitude: ≤1000m. 3. Relative humidity : Daily average≤95% ,daily averange of vapour pressure≤2.2kpa Monthly average≤90%,monthly averange of vapour pressure≤1.8kpa. 4. Earthquake intensity: ≤magnitude 8. 5. Applicable in the places without corrosive and flammable gas. Note: Customized products are available. Features 1. Modular design, where each unit module c...
RN1 Indoor Current Limiting Fuse
Features Current which passes the fuse when being1.3 times of itsspecified electric current,Do not fusing for an hour; Whenthe current through the fuse is 2 times of its specinedelectric current,fusing in an hour;Refer to its fusingfeature curve in chart 1when select the fuse. Figure 1 RN1/RN3“An-second” characteristic curve Technical data 3 6 10 35 Rated current (A) 20 100 200 300 400 200 75 100 200 300 20 50 75 100 200 7.5 10 20 30 40 Max breaking curent KV effective vakue 40 1.3...