LFSB-10 Current Transformer
Selection Structural introduction This type of current transformer is fully enclosed and post type. It has a good ability of insulation, moisture proof and antipollution. It is small and light. It can be installed at any place and any direction. Technical data 1. Rated insulation level: 12/42/75kV; 2. Rated secondary current: 5A,1A; 3. Refer to the table for rated primary current, accuracy classed combination, rated output, rated dynamic and thermal current. 4. The conditions of partial disc...
FLN36 Indoor SF6 Load Switch
Selection Operating conditions 1. Air temperature Maximum temperature: +40℃; Minimum temperature:-35℃. 2. Humidity Monthly average humidity 95%; Daily average humidity 90%. 3. Altitude above sea level Maximum installation altitude: 2500m. 4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 5. No frequent violent shake. Technical data Ratings Unit Value Rated voltage kV 12 24 40.5 Rated lighting impulse withstand voltage kV 75 125 170 Common value Acro...
FZW28-12F Outdoor Vacuum Load Switch
Selection Operating conditions 1. Altitude: ≤ 2000 meters; 2. Environment temperature: -40℃ ~+85℃; 3. Relative humidity: ≤ 90% (25℃); 4. The maximum daily temperature difference: 25℃; 5. Protection grade: IP67; 6. The maximum ice thickness: 10mm. Technical data Item Unit Parameter The switch body Rated voltage kV 12 Power frequency insulation withstand voltage (Interphase and phase to ground / fracture) kV 42/48 Lightning impulse withstand voltage (Interphase and phase to groun...
ZW32-12 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -30℃ 2. Altitude ≤ 2000 meters 3. Wind pressure: no more than 700Pa (corresponding to the wind speed 34m/s) 4. Earthquake intensity: do not exceed 8 degree 5. Pollution grade: III class 6. Maximum daily temperature: less than 25℃ . Technical data Item Unit Parameter Voltage, current parameters Rated voltage kV 12 Rated short time power frequency withstand voltage (1min) kV 42/48 Rated l...
GCS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ Daily average temperature: ≤35℃ When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Altitude: ≤2000m 3. Relative humidity: ≤50%, when temperature is +40℃ When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation. 4. Installation inclination: ≤5% 5. Applicable in the...
S9-M Oil-immersed Transformer
Selection Operating conditions Ambient temperature: maximum temperature: +40°C, minimum temperature: -25℃. Average temperature of the hottest month:+30℃, average temperature in the hottest year: +20℃. Altitude not exceeding 1000m. The waveform of the power supply voltage is similar to a sine wave. The three-phase supply voltage should be approximately symmetrical. The total harmonic content of the load current shall not exceed 5% of the rated current. Where to use: indoors or outdoors. Featu...