ZW32-24 Outdoor Vacuum Circuit Breaker
Selection Operating conditions 1. Ambient air temperature: The daily temperature variation: -40℃ ~+40℃ diurnal variation of temperature less than 25℃; 2. Altitude: no more than 2000 meters 3. Wind speed is no more than 35m/s (equivalent to 700Pa on the surface of the cylindrical); 4. Ice cover thickness no more than 10mm; 5. The intensity of sunshine not more than 1000W/m ² 6. Pollution degree no more than GB 5582 IV class 7. Seismic intensity does not exceed 8 class 8. No flammable, explosi...
KYN28-24 Metalclad AC Enclosed Switchgear, With...
Selection Operating conditions 1. +15°C~+40°C. And the average value measured within 24 hours shall not exceed 35°C 2. The average monthly relative humidity shall not exceed 90% The average monthly water vapor pressure shall not exceed 1.8kPa; 3. Altitude: ≤1000m. 4. There is no obvious dust or smoke in the surrounding air: pollution caused by corrosive or combustible gases, vapors, or salt mist; 5. Vibration or ground motion from outside the switchgear and control equipment can be ignored; ...
JN22-40.5/31.5 Indoor Grounding Switch
Selection Operating conditions 1. Ambient temperature:-10~+40℃ 2. Altitude: ≤1000m 3. Relative humidity: Day average relative humidity ≤95% Month average relative humidity ≤90% 4. Earthquake intensity: ≤8degree 5. Appliable in the place without corrosive, flammable gas and water place 6. With no frequently intense vibrant place around. Technical data Item Units Data Rated voltage kV 35 Maximum voltage kV 40.5 Rated short time withstand current kA 31.5 Rat...
SC(B)9 Series Epoxy Resin Dry-type Transformer
Selection Operating conditions 1. Ambient temperature: maximum temperature: +40°C, minimum temperature: -25℃ . 2. Average temperature of the hottest month:+30℃, average temperature in the hottest year:+20℃ . 3. Altitude not exceeding 1000m. 4. The waveform of the power supply voltage is similar to a sine wave. 5. The three-phase supply voltage should be approximately symmetrical. 6. The relative humidity of the surrounding air should be lower than 93%. 7. And there ...
GCS Low-voltage Switchgear Panel, Withdrawable ...
Selection Operating conditions 1. Ambient air temperature: -15℃ ~+40℃ Daily average temperature: ≤35℃ When the actual temperature exceed the range, it should be used by reducing the capacity accordingly. 2. Altitude: ≤2000m 3. Relative humidity: ≤50%, when temperature is +40℃ When temperature is low, larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation. 4. Installation inclination: ≤5% 5. Applicable in the...
ZN63 (VS1)-12C Vacuum Circuit Breaker (Side-Ope...
Selection ZN63 C - 12 P / T 630 - 25 FT R P210 Name Structure - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) - Rated short-circuit breaking current(KA) Installation Main circuit wiring direction Phase distance Indoor vacuum circuit breaker Side operation - 12:12KV No mark: Insulating cylinder type P: Solid-sealing type / T:Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 FT: Fixed type L: Left R: Right P210 Note: 1. order a ZN63 si...