FN AC High-voltage Load Switch
Selection Technical data Rated voltage(kV) Highest voltage(kV) Rated current(A) Industrial frequency voltage withstand in 1min(kV) 4S thermal stable current (effective value)(A) 12 12 400 42/48 12.5 12 12 630 42/48 20 Active stable current (peak value)(A) Short circuit close current (A) Rated open current (A) Rated transfer current (A) 31.5 31.5 400 1000 50 50 630 1000 Type Full type DS Earthing switch at inlet position DX Earthing switch at inlet position L Interlock...
LZZBJ9-10 Current Transformer
Selection Technical data 1. The performance of products is conformed to IEC standard and GB1208-2006 Current Transformer. 2. Rated insulation level: 12/42/75kV 3. Load power factor: cosΦ =0.8(Lag) 4. Rated frequency: 50Hz 5. Rated secondary current: 5A, 1A 6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC. Model Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA vir...
ZN28-12 Indoor Vacuum Circuit Breaker
Selection Operating conditions 1. The environment temperature: upper limit +40℃, lower limit -15℃; 2. Altitude: ≤2000m; 3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%; 4. Earthquake intensity: less than 8 degrees; 5. No fire, explosion, pollution, chemical corrosion and severe vibration place. Technical data Item Unit Parameter Parameters of voltage, current, life Rated voltage kV 12 Rated short time power frequency with...
RN2 Indoor Current Limiting Fuse
Technical data Product type RN2-3、6、10 RN2-15、20 RN2-35 Rated voltage 3 6 10 15 20 35 KV Fuse current A 0.5 0.5 0.5 Capacity of largest break of three-phase MVA 500 1000 1000 1000 Max break curent KA effective value KA 500 85 50 40 30 17 Overvoltage multiple Do not exceed voltage of 2.5 times of rating Resistance of the fuse pipe (Ω) 93±7 200±10 315土14 Weight Kg 5.6 12.2 15.6 Fuse weight Kg 0.9 1.6 2.5 Overall and mounting dimensions(mm)
JXF Low-voltage Integrated Distribution Box
Selection Operating conditions 1. Installation Site: Indoor or outdoor; 2. Atitude: No more than 2000m. 3. Earthquake lntensity: No more than 8 degrees. 4. Ambient Temperature: No more than +40℃ and no less than -25℃.Averagetemperature is no more than +35℃ within 24 hours. 5. Relative Humidity: the average daily value is no more than 95%, the averagemonthly value is no more than 90%. 6. Installation locations: without fire,explosion danger,serious pollution,chemical corrosion and violent vi...
ZN63 (VS1)-12C Vacuum Circuit Breaker (Side-Ope...
Selection ZN63 C - 12 P / T 630 - 25 FT R P210 Name Structure - Rated voltage(KV) Pole type / Operating mechanism Rated current(A) - Rated short-circuit breaking current(KA) Installation Main circuit wiring direction Phase distance Indoor vacuum circuit breaker Side operation - 12:12KV No mark: Insulating cylinder type P: Solid-sealing type / T:Spring type 630 1250 1600 2000 2500 3150 4000 - 20 25 31.5 40 FT: Fixed type L: Left R: Right P210 Note: 1. order a ZN63 si...